Please check the specification book to determine if your specialty is included in this project. If it is not, we apologize for the inconvenience and ask that you disregard this ITB.



TO VIEW PLANS AND SPECS:
https://florenceplanroom.com/
CLICK ON CUSTOMER LOGIN -
USERNAME: FBIC
PASSWORD:  bids 
CLICK ON DOCUMENT LIBRARY
AT LEFT OF SCREEN ON BLUE
BACKGROUND
SCROLL DOWN LIST OF JOBS

INVITATION TO BID

Conway Office
Please use this fax number:
(843) 234-4326

Phone:
(843) 665-0408

Cast-In-Place Concrete 
Unit Masonry 
Cast Stone Masonry 
Cold Formed Metal Framing 
Metal Fabrications
Misc. Carpentry 
Interior Finish Carpentry 
Wood-Veneer-Faced Architectural Cabinets 
Plastic-Laminate-Faced Architectural Cabinets 
Fiberglass Reinforced Polyester 
Thermal Insulation 
Weather Barriers 
Fiber Cement Siding & Trim 
Thermoplastic polyolefin (TPO) roofing 
Sheet Metal Roofing 
Sheet Metal Flashing & Trim 
Roof Accessories 
Penetration Firestopping 
Joint Sealants 
Door Hardware Schedule 
Aluminum Frames 
Wood Doors 
All-Glass Entrances & Storefronts 
Aluminum-Framed Entrances & Storefronts
Glazed Aluminum Curtainwall 
Door Hardware 
Glazing 
Common Work Results for Flooring Preparation
Mirrors
Specialty Film for Glazing 
Non-Structural Metal Framing Gypsum Board 
Tiling 
Acoustical Ceilings 
Linear Metal Ceilings 
Resilient Base & Accessories 
Resilient Tile Flooring 
Tile Carpeting 
Fiberglass Reinforced Plastic Panels 
Exterior Painting 
Interior Painting 
High-Performance Coatings 
Plastic-Laminate-Clad Toilet Compartments 
Toilet & Bath Accessories 
Fire Protection Specialties 
Custom Aluminum brackets 
Manual Window Shade Systems 
Motorized Roller Window Shades 
Countertops 
Entrance Floor Mats & Frames 
Fire Supression 
Plumbing 
HVAC 
Electrical 
Fire Alarm Systems 
Rock Removal 
Unsuitable Soil Removal 
Termite Control 


The project will consist of a one-story 7,627 square foot steel-framed structure with drive thru canopy Max. Column loads: 80 kips (assumed) Max. Wall loads: 3 kips per linear foot (assumed) Maximum 2 feet of fill and 1 foot of cut to achieve final grades (based on DDC Engineers Grading and Drainage Plan dated 11-27-18) with Little excavation other than foundation construction

Estimator:

Kent Gunter


Will your company be bidding?  Please click Yes or No

Yes
No

Job Opportunities

Renew your Membership

Please select your membership category, our staff will contact you to collect additional information.

HCAC Membership Levels

HCAC Mission

Our mission is to provide the necessary resources to ensure the continued progress of our members, while promoting the long term success of Hispanic-owned construction businesses in the Carolinas.

Login Form